SiteOmat Setup and Maintenance Manual – MDE 4817G
3-6. INSTALLATION SCREENS
The Installation section enables the user to install the following application and components
described below:
• SiteOmat
• OrData
• Pump Server
• PAIS
• Operating System
3-6.1. SiteOmat
As a rule the SiteOmat is pre-installed, at the factory level, in the OrCU. However, whenever
required, SiteOmat can be installed in the OrCU in the station.
NOTE
Before installing SO versions 6.4.42 and up, upgrade
BSP (OrCU Operating System) to version 1.08 SP 9
(see Section 3-6.5).
From this version on, OrCU Administrator setup
web connects to OrCU unit using a secure link
(HTTPS).
Prior to installing SiteOmat, proceed as follows:
1. Obtain the SiteOmat installation files. The SiteOmat installation file is named as:
FCC_ORCU_dd_mm_yy a_b_ccc.exe
Where: dd_mm_yy is the date the files were built, and a_b_ccc is the version.
For example: File FCC_ORCU_28_02_11 6_3_300 was built on 28/02/11, version
number is 6.3.300.
In cases where upgrading SiteOmat to a later version, verify the following:
CAUTION
These procedures, if not strictly observed, could
result in damage to the setup and database of the
system.
1. All station activities are stopped
2. All the transactions have been transferred to the Head Office
3. FCC was stopped, by clicking on the Stop button on the Sys Commands screen (see
paragraph 8-2)
4. Station DB was back-upped (see paragraph 8-3)