SiteOmat Setup and Maintenance Manual – MDE 4817G

Click Modify to save the selections and Close to close the dialog box and return to the Global tab;

or click Close to exit the dialog box without saving the changes.

6-3.1. Open Door Detection

The FFC includes a feature for preventing unauthorized third parties from forcing the sealed FCC

box door.

The FCC generates an alarm in cases where the door was opened: "The door is open".
The function setup procedure comprehends:

a. Physical installation and setup of the detector (described in 8-Port Commverter

Operation and Installation Manual MDE-4820)

b. Feature activation in SiteOmat, as described below:

To activate open door detection, select the Enabled checkbox and set the detector's IP and Port as

defined in the 8-Port Commverter.

6-3.2. Payment Terminal Setup

To set the SiteOmat connection to a third party clearing system, click on the Setup button in the

Payment Terminal section in the Station Parameters screen. The Setup PAIS dialog box appears

(see Figure 6-3).

The various parameters are described in Table 6-3.

Figure 6-3. Setup PAIS Dialog Box –FiPay Processor Specifics