Gasboy SiteOmat Maintenance Manual User Manual
Page 169

165
SiteOmat Setup and Maintenance Manual – MDE 4817G
transaction does not match the newly set price
• Update price whenever a connection between the pump and the
Controller was lost
• The Update Price before any transaction option is disabled
Flow Rate
Verifies that the flow is not larger than x gallons/litters per minute for
mechanical pumps only. The default is disabled and the flow rate is defined
as zero. In cases where the option is enabled and the flow exceeds the
predetermined value (i.e. actual flow is 100 gallon/min, defined flow rate is
60 gallon/min) the controller stops the fueling.
Authorization
Parameters
Defines the Number of Retries allowed to the customer and the maximum
delay between retries
before the pump shuts off for the customer. Users
can also Force a pump check of its authorization definitions by defining its
rate in seconds.
External EFT
Optional, requires integration with 3
rd
party applications.
Defines system with external Electronic Funds Transfer capability (i.e. the
authorization process is done in an external system and not in the SiteOmat
system.)
Define the type of EFT available in the system from the drop-down list.
Vehicle Must Be Defined In SiteOmat
: Vehicles must also be defined in a
list in the SiteOmat, if this checkbox is selected.
7-11.5. Finalizing Pump Settings
Once all the parameters have been defined, proceed as follows:
1. Click Save to store all the settings and return to the Setup Pump Settings dialog box
2. Click Save to save the changes and return to the Setup screen
7-11.6. Deleting Pump
To delete a pump from the list, proceed as follows:
1. Select it by clicking on its row
2. Once its parameters are displayed, click Delete. The pump is deleted from the list.
However, a pump cannot be deleted if it is currently in use.