113

SiteOmat Setup and Maintenance Manual – MDE 4817G

changes

d. Enable manual totalizers: Select this checkbox to

manually enter mechanic pump totalizers. Please refer to

Section 6-7. of MDE 4818.

e. Card number automatically generated: Select this

checkbox to enable Card Numbers generation for not burned

devices. The vehicle is identified by its plate number and

automatically receives a device number after the first

refueling

f. Allow auto authorize pump from OrPT: Select this

checkbox to allow Shift Managers to switch the pump

operation modes from Need Authorize to Auto-Authorize

mode through ORPT

g. Record Fuel Start Flow Time: Select this checkbox to

include in transaction record the time stamp when the pump

started to supply fuel, namely changed to IN_USE state

TLG Update Intervals

Sets the intervals for receiving Delivery, Inventory and Alarm

updates from the TLG system.

Enclosure door open

detection

See paragraph 6-3.1

Discovery Mode

Activates/deactivates automatic recognition of Series 1000 devices.

The system authorizes Series 1000 cards/keys on the first fueling,

identifying rules and limits and adds the device to SiteOmat's

database.

OrPT Beeps

Provides sound feedback each time a device is detected. Select the
Allow beeps

checkbox to activate the feature and enter the required

# of beeps

. In cases where more than one OrPT is installed at the

station, it is required to associate the dispenser to a specific OrPT

terminal (please refer to paragraph 7-11)

Status Screen Beeps

Provides sound feedback on Status Screen each time a nozzle is

lifted. Select the Allow beeps checkbox to activate the feature and

enter the required # of beeps

Activate Manager Tag

Reactivates the Manager Screen on the OrPT, which enables the

technician to perform test transactions with the Manager Tag

provided with OrTOP controllers. After disabling this feature from

OrPT screen, the system cleans all test transactions, initializes all

counters in the database and deactivates the Test Transaction

option. Manager Tag option is enabled by default when Manager

Screen is active