4.5.11. lock miss use log (debuglock.log), This log records improper use of locking mechanism – Gasboy SiteOmat Maintenance Manual User Manual

Page 209

background image

205

SiteOmat Setup and Maintenance Manual – MDE 4817G

8-4.5.10.1.30. Error: Pumps must be in IDLE for shift open / close:

[2007-12-11 14:29:28.218 00005436] ERROR: can't read totalizers from pump 1 - process is (1)
should be 1 status is (48) should be (49)

8-4.5.10.1.31. Pump server not responding, sending
restart request to FCC Loader:

[2007-02-03 01:16:17.093 00012210] PS (ID=200000012): time of last comm 4571703 far from current
4577093 more than 4 seconds while last check was at 4576753
[2007-02-03 01:16:17.093 00012210] FCC watchdog: sending restart to PS ID=200000012

8-4.5.11. Lock Miss use Log (DebugLock.log)

This log records improper use of locking mechanism.

There exists only one such log file exists on BOS and FCC.

This log file is intended for development use only.