SiteOmat Setup and Maintenance Manual – MDE 4817G

Figure 7-25. Pump Server Settings Screen

First, in the General section select the pump Type (protocol) that is to be linked to this Pump

Server. Next, define the Authorization TimeOut for the pump, in seconds. This parameter sets the

time for stopping the pump, when the pump is authorized but there is no fuel flow.

It is highly recommended not to define the Logging section parameters. Only Gasboy certified

technicians should enable this feature. Logging enables data transfer between the pump and the

pump server.

To enable Logging, click on the appropriate checkbox, as described in Table 7-3:

Table 7-3 Logging Section Parameters

Parameter

Description

Pump Communication:

Enables generation of Pump- Pump Server communication

logs.

Comm (FCC)

Communication:

Enables generation of Controller- Pump Server communication

logs. The connection Port must be defined.

Application:

Enables application logs generation on the Pump Server. The

connection Port must be defined.

By setting the ports the logs could be monitored with a Telnet terminal without enabling the logs.