beautypg.com

Gasboy SiteOmat Maintenance Manual User Manual

Page 131

background image

127

SiteOmat Setup and Maintenance Manual – MDE 4817G

The Target of the Backup can be an FTP server or a Path.

If the FTP or HTTP option is selected, identify the URL and the Port. Also, the user Password

should be entered.

If a Path is selected, enter its identification.

To test the backup, click on the Backup Now button. This procedure performs an immediate, full

backup to the defined target. A binary file is created in the FTP server; in cases where using the

delta mode, TXT files are created. Those files can be accessed in the restore process only (see

section 8-3), do not open them with other applications.

NOTE

Prior to the Backup Now procedure, click on the
Save

button to save the settings.

Otherwise, a warning message is displayed (see Figure 6-10). Click OK to save the settings.

Figure 6-10. Save Data Message

6-8. SERIES 1000

The Series 1000 button opens the Series 1000 Upgrade pages of the Setup Wizard, enabling the user

to define Series 1000 cards/keys authorization parameters, in cases where SiteOmat replaces the

Series 1000 legacy system.

Please refer to paragraphs 4-4.10 and 4-4.11.