beautypg.com

Gasboy SiteOmat Maintenance Manual User Manual

Page 187

background image

183

SiteOmat Setup and Maintenance Manual – MDE 4817G

NOTE

The Log Server should be used only when advised

by Orpak technical support and cannot be used for

low band networks such as dialup or GPRS.

Table 8-4. SiteOmat Logs

Log

Description

FCC – System

System startup, configuration reading, cleanup, etc.

FCC – External

Commands from BOS, setup, stop, start, reload, log level

change

FCC – Shift

Shift close/open related operations including totalizers

reading, attendant management, batch receipt generation

FCC – Wet Stock

Tank and TLG related operations, such as deliveries

FCC – Fueling

All operations related to fueling transactions, authorization

(including PAIS), price update

BOS – System

System startup, cleanup, etc.

BOS – External

Communication with HO

BOS – Forecourt Controller

(FCC)

Communication with FCC, including data reception and

requests authorization

BOS – User Related

All user actions, reports generation, import/export

Table 8-5. Log Levels

Level

Description

Critical

Information required for reconstructing transactions data, including

authorizer and quantities

Error

Abnormal system events causing wrong behavior (i.e. Fail to open shift,

Error write transaction to DB)

Warning

Events that do not affect system functionality but point out a problem (i.e.

Transaction already written – which may indicate slowness of the system)

Information

Additional information which may help in clarifying the data flow or

operational scenarios, without details on the specific operation

Debugging

Information which may help in identifying relevant code segments to

understand the logic of the system (i.e. Print variable content of IF clauses,

Print result of a function, Print system error code)

Trace

Very detailed debug level to be used in cases where the total flow of code

is required to analyze a problem (i.e. Enter and exit of each function)