Gasboy SiteOmat Maintenance Manual User Manual
Page 187

183
SiteOmat Setup and Maintenance Manual – MDE 4817G
NOTE
The Log Server should be used only when advised
by Orpak technical support and cannot be used for
low band networks such as dialup or GPRS.
Table 8-4. SiteOmat Logs
Log
Description
FCC – System
System startup, configuration reading, cleanup, etc.
FCC – External
Commands from BOS, setup, stop, start, reload, log level
change
FCC – Shift
Shift close/open related operations including totalizers
reading, attendant management, batch receipt generation
FCC – Wet Stock
Tank and TLG related operations, such as deliveries
FCC – Fueling
All operations related to fueling transactions, authorization
(including PAIS), price update
BOS – System
System startup, cleanup, etc.
BOS – External
Communication with HO
BOS – Forecourt Controller
(FCC)
Communication with FCC, including data reception and
requests authorization
BOS – User Related
All user actions, reports generation, import/export
Table 8-5. Log Levels
Level
Description
Critical
Information required for reconstructing transactions data, including
authorizer and quantities
Error
Abnormal system events causing wrong behavior (i.e. Fail to open shift,
Error write transaction to DB)
Warning
Events that do not affect system functionality but point out a problem (i.e.
Transaction already written – which may indicate slowness of the system)
Information
Additional information which may help in clarifying the data flow or
operational scenarios, without details on the specific operation
Debugging
Information which may help in identifying relevant code segments to
understand the logic of the system (i.e. Print variable content of IF clauses,
Print result of a function, Print system error code)
Trace
Very detailed debug level to be used in cases where the total flow of code
is required to analyze a problem (i.e. Enter and exit of each function)