175

SiteOmat Setup and Maintenance Manual – MDE 4817G

For usage and download refer to http://www.baremetalsoft.com/wintail/

8-1.2. IP Addresses and Connections

For service reasons, these ports must be opened to allow communications into the SiteOmat 22,

443, 80, 8090 (consult the IT manager).

SiteOmat connects over a secure link; HTTPS (SSL) communications layer. To access the unit use

Internet Explorer and navigate to https://SiteOmatIP (e.g. https://192.168.1.104)

A default administrative user has been created. The default username is ‘Admin’ and the default

password is ‘Admin’.

For the OrCU management, a separate management exists for network and time settings. Access

this management by HTTP (not SSL) http://xxx.xxx.xxx.xxx:8090 (x= the ORCU IP Address, e.g.

http://192.168.1.104:8090)

A user/password is required; the system comes with user ‘admin’ password ‘admin’ defaults.
All usernames and passwords are case-sensitive.
The OrCU unit comes with two Ethernet controllers that are defaulted, with the following IPs:
LAN1 – 192.168.1.104 Mask 255.255.255.0
LAN2 – 10.0.0.1 Mask 255.255.255.0

LAN1 must be used for communicating with station devices and LAN2 for communicating with

outside world (such as FHO or other remote host).

8-1.3. Regular FCC Maintenance Operation

8-1.3.1. FCC Transaction Limit

Due to the storage limit of the OrCU hardware, the number of transactions is limited to 25,000. The

number of devices (or vehicles) that can be defined is limited to 50,000.

There are two ways by which transactions can be downloaded from the SiteOmat to free up space in

the transaction database:

a. Using Data Downloader – see more details in section 8-8.
b. Using Fleet Head Office

8-1.3.2. Disk Usage Thresholds

When the SiteOmat detects that disk usage exceeds 60%, an alarm (FCC Hard Disk Almost Full)

is generated and the system tries to clean and free disk space automatically.

When the disk usage exceeds 70%, another alarm (FCC hard disk full) is generated, and the

station is stopped. All communication to devices is halted and new transactions are not permitted.

In addition if DB size exceeds 5MB in the FCC module or 100 MB in the BOS module, the station