beautypg.com

Gasboy SiteOmat Maintenance Manual User Manual

Page 191

background image

187

SiteOmat Setup and Maintenance Manual – MDE 4817G

Copy all (uncompressed) files

to /usr/local/orpak/BOS/DB

For each file (FILENAME) run the following # sqlite3

DATA.DB < FILENAME

Run the files in ascending order of dates (first comes

first) older date first!

7. Verify that the files and folders permissions are correct

# cd /usr/local/orpak/BOS

# chown –R fcc:fcc *

c. FCC DB

1. Before FCC can start, it DB must be properly set – do not start operating the

station and making transactions or any other operation before completing this

procedure

2. Reboot the OrCU to load all components

3. Verify that the BOS is operational and the setup looks OK – (browse to the

SiteOmat)

4. From Admin menu run Sysinit

5. From Admin menu run Sync FCC - this command verifies that the FCC DB

indexes are matched

6. From Admin menu run Reload – this must be the last action