7-11.3.1. Mechanical Pump Specific Parameters
The MPI-C specific parameters are described in Table 7-6:
Table 7-6. Specific Parameters Settings for MPI-C Pumps
Parameter
Description
Default
Nozzle Polarity
Normal/inverse for IN USE Signal
(Signal/No signal when nozzle lifted)
Normal
Pulse Factor
Number of pulses per Liter/Gallon (1000
resolution)
Pulser Type
Pulser Counting Type (Half Cycle Count
Pulse, Full Cycle Count Pulse, 90
Degrees Phase Pulser)
Half Cycle Count Pulse
Virtual In Use
When Enabled, The Idle state is forced to
Call state.
Disable
Single/Dual Valve
Mode
Use of single/dual valves per pump
(Single - One pump with two valves (fast
valve + slow valve), Dual - Two pumps
with one valve each)
Dual pumps one valve each
Flow Protection
timeout (Seconds)
Number of seconds without fuel flow
before forcing stop
60
Additional Flow
Protection timeout
(Seconds)
Number of seconds without fuel flow
when refueling with VIUs before forcing
stop. This parameter is relevant for
pumps configured with Virtual In Use
Maximum volume
rate per minute
Defines the maximum fuel volume
allowed per minute, used for abnormal
pulse rate issues.
When this option is enabled, this
parameter must be higher than the pump
maximum volume rate.
0