Gasboy SiteOmat Maintenance Manual User Manual
Page 34

30
SiteOmat Setup and Maintenance Manual – MDE 4817G
SECTION 2
PRE-SETUP INFORMATION
2-1. GENERAL
This section provides the preliminary information required for configuring the SiteOmat software.
This procedure consists of defining the devices and communication buses in the system, necessary
for the installation and setup of SiteOmat.
2-2. SETUP DEFINITION INFORMATION
2-2.1. Required Setup Information
The Controller system – Islander PLUS, CFN PLUS, and Fuel Truck Controller - is provided with
the SiteOmat software already installed in OrCU.
Therefore, the setup procedures consist of defining the different buses or communication channels
that transport data to/from the controller systems.
Then the devices connected to the Controller and their operating attributes must be defined. These
devices range from pumps, payment devices up to the optional printer.
2-2.2. Required Setup Information – Example
Figure 2-1 shows the required setup information for the pump server and a pump.
First, the user is required to define the pump server bus that transports data to/from the OrCU. This
Pump Server is an internal software module within the OrCU. The user is required to enter its IP
address, port and frame. This information is provided in Table 2-1 and Table 2-2.