9. Set the peripherals communication parameters in the 8-port CommVerter (see
details in MDE-4820)
10. If needed, configure the controller operating system in the OrCU
Administration screen (see section 3)
11. Browse to the SiteOmat Wizard and setup the station (see section 4)
12. Set specific station parameters (See section 5)
13. For advanced settings: change global default settings (See section 6) or
forecourt devices default settings (See section 7)
14. Save the settings and Reload the system
15. Backup (See section 8-3)
16. In cases where mechanical pumps are in use, put the channel in Bypass and
check that the pump refuels (see below)
17. Remove the channel from Bypass
18. Verify that the MPI-C Inuse LED is on when taking out the nozzle
19. Verify that the MPI-C pulser LED is blinking when fueling
20. Use the status screen to produce a full transaction by clicking on the pump
icon
21. Verify that the decimal points are identical to those in the pump, set the
SiteOmat accordingly and click Reload
22. Go to Fleet Management and add a testing fleet and a vehicle tag/card/key
(use Acquire if installing Islander PLUS). Do not use a real fleet code. This
device should not be added to the Head Office in later steps
23. Check the refuel process using the authorization device defined for testing
24. Get advise from the IT manager on the external IP address of the controller
for external communication
25. Got to the Administrator screen and change "eth1" accordingly (see
paragraph 9-3.3)
26. In Head Office:
a. Verify that the PC complies with the specifications indicated in the
manual
b. Check the connection to internal Intranet or External Internet (get
help from IT)
c. Install the HO
d. From the HO computer, check the connection to the Controller (use
"PING" command or browse to it)
e. Set the HO global parameters
f. Set the products