177
SiteOmat Setup and Maintenance Manual – MDE 4817G
• Performing the same operations (start-up, monitoring, and restart) for multiple pump
server processes
• FCC Loader records its actions in a log file
8-1.6.1. Pump Server
The pump server is an active device that communicates between FCC and the pumps. If no data is
received from a pump server, the watchdog checks status of the first pump in each cluster.
8-1.6.2. Pump Server ‘ini’ Files
The Pump Server ini files are created by the SiteOmat, based on the Setup information configured
on the BOS. The ini files are located in the /usr/local/orpak/bin directory on the FCC.
Table 8-1 shows the syntax and semantics of the Pump Server ini files.
Table 8-1. Pump Server INI Files
[logging]
Log parameters
Single within the
file
log_spec_output_dir
Common Output
Directory
Full path to the common
log files and runtime
backup directory
String
'/' (slash) character at the
end of the string
Unique: Dir name + File
name
Process
working
dir.
log_stat_output_dir
Status File Output
Directory
Full path to the runtime
backup directory
String
'/' (slash) character at the
end of the string
log_spec_o
utput_dir
start_up_log_name
Startup Log File Name
Start up log file name
String
Following the log file
names convention…
log_app
Update System Log In
File?
Enable system (Pump
Server) log file output?
String
Y/N
Y
app_log_name
System Log File Name
System log file name
String
Following the log file
names convention…
log_app_size
System Log File Size
System log file maximal
size
Integer
-1 – unlimited
> 0
200000
log_app_port
System Log File Port
Port number for run-
time debug of the system
log
Integer
> 1023
Unique within 'localhost'
0 – not used
0
log_scucomm
Update SCU Log In File?
Enable log file output
for the communication
with the SCU?
Boolean
Y/N
N
scu_log_name
SCU Log File Name
SCU log file name
String
Following the log file
names convention…
log_scucomm_size
SCU Log File Size
SCU log file maximal
size
Integer
-1 – unlimited
> 0
100000
log_scu_comm_port
SCU Log File Port
Port number for run-
time debug of the SCU
Integer
> 1023
0