beautypg.com

Gasboy SiteOmat Maintenance Manual User Manual

Page 181

background image

177

SiteOmat Setup and Maintenance Manual – MDE 4817G

• Performing the same operations (start-up, monitoring, and restart) for multiple pump

server processes

• FCC Loader records its actions in a log file

8-1.6.1. Pump Server

The pump server is an active device that communicates between FCC and the pumps. If no data is

received from a pump server, the watchdog checks status of the first pump in each cluster.

8-1.6.2. Pump Server ‘ini’ Files

The Pump Server ini files are created by the SiteOmat, based on the Setup information configured

on the BOS. The ini files are located in the /usr/local/orpak/bin directory on the FCC.

Table 8-1 shows the syntax and semantics of the Pump Server ini files.

Table 8-1. Pump Server INI Files

[logging]

Log parameters

Single within the

file

log_spec_output_dir

Common Output

Directory

Full path to the common

log files and runtime

backup directory

String

'/' (slash) character at the

end of the string

Unique: Dir name + File

name

Process

working

dir.

log_stat_output_dir

Status File Output

Directory

Full path to the runtime

backup directory

String

'/' (slash) character at the

end of the string

log_spec_o

utput_dir

start_up_log_name

Startup Log File Name

Start up log file name

String

Following the log file

names convention…

log_app

Update System Log In

File?

Enable system (Pump

Server) log file output?

String

Y/N

Y

app_log_name

System Log File Name

System log file name

String

Following the log file

names convention…

log_app_size

System Log File Size

System log file maximal

size

Integer

-1 – unlimited

> 0

200000

log_app_port

System Log File Port

Port number for run-

time debug of the system

log

Integer

> 1023

Unique within 'localhost'

0 – not used

0

log_scucomm

Update SCU Log In File?

Enable log file output

for the communication

with the SCU?

Boolean

Y/N

N

scu_log_name

SCU Log File Name

SCU log file name

String

Following the log file

names convention…

log_scucomm_size

SCU Log File Size

SCU log file maximal

size

Integer

-1 – unlimited

> 0

100000

log_scu_comm_port

SCU Log File Port

Port number for run-

time debug of the SCU

Integer

> 1023

0