SiteOmat Setup and Maintenance Manual – MDE 4817G

G.3.3. Card Number Generation

The Magnetic Card or Data Key devices account field excluding the System ID will be pushed to

the FHO’s Device database to generate the Card Number (see Figure G-13)

Figure G-13. Generated Card Numbers

NOTE

Once the initial devices have been discovered,
never activate the Discovery mode again

.

G.3.4. Editing the Devices

The Devices in the FHO database can now be edited to the customer’s specifications:

1. New Rules can be added to the existing Series 1000 Rules (Fuel limitations and

Authorizations) and applied to the Group Rules

G.3.5. Final Wrap Up

1. Log back into the SiteOmat: Setup Global Advanced, unselect the Discovery mode

and then click Modify.