AMETEK Lx Series II Programming Manual User Manual
Page 99

Programming Manual
Lx \ Ls Series II
95
VOLTage:REFerance
This command select the referance Voltage. The following voltage refernace can be selected:
INTernal
This is the internal voltage referance for programmable voltage
EXTernal
This is the external DC voltage referance input to program the output
voltage. 0 to +10 voltage represents 0 to full scale output voltage. This is
the RPV option.
Command Syntax
[SOURce:]VOLTage:Refernace
Parameters
INTernal | EXTernal
*RST Value
INTernal
Examples
VOLT:REF EXT
Query Syntax
[SOURce:]VOLTage:REFerance?
Returned Parameters
Related Commands
VOLT:ALC:SOUR OFF
Note: The VOLT:ALC:SOUR command must be set to off prior to selection of the referance to
external.