SYNTAX
DESCRIPTION
CURLB
Set the current limit value followed by numeric value (9023)
CURLC
Set the current limit value followed by numeric value. (9023)
CURLS
Set the current limit value followed by numeric value for all phases
on 3 phase models. (9023)
FREQ
Set the frequency value followed by numeric value.
PANGA
Programs the phase A angle on a
–LKS relative to the Master. This
command can only be send to the auxiliary unit in a clock and lock
system. See SYNC command.
PANGB
Programs the phase B angle with respect to phase A. (9023)
PANGC
Programs the phase C angle with respect to phase A. (9023)
RNG
Set the voltage range value
For single-phase power sources:
0 = Low voltage range
1 = High voltage range.
For three phase power sources:
1 = Low voltage range
2 = High voltage range
Note: Sending RNG0 to a 3 phase AC unit will also result in the low
voltage range being selected. Although CI units do not have a 67.5
V range, if enough current is available from the AC source, the
135V or 150V range can be used. This will avoid errors being
generated when running existing code.
Note that for this command to work, the output relay must be open.
See OPN command.
RNGF
Set the upper frequency limit where n is as follows:
0
Up to 100Hz.
1
Up to 1000Hz. (compact iX) or up to 5000 Hz (Lx/Ls)
2
Up to the frequency limit of the source. For compact iX, this
is also 1000 Hz up to 5000 Hz (Lx/Ls)
CLS
Close the output relay.
OPN
Open the output relay.
LOCK
Will disable the output voltage fault generated by the Automatic
level control of the source, also will disable the current limit fault.
UNLK
Will enable the fault generated by the Automatic level control and
will enable the current limit fault.
ZERO
When this command is send, with the Voltage or Frequency setting,
the change of Voltage or frequency will occur at the zero crossing of
the wave form. The command is only effective at the time is send.