Programming Manual

Lx \ Ls Series II

185

SYNTAX

DESCRIPTION

PEAK

When this command is send, with the Voltage or Frequency setting,
the change of Voltage or frequency will occur at the peak of the
waveform. The command is only effective at the time is send.

OVER

This command will be accepted but will not disable the error
detection of frequency or voltage values that exceed the source
limits.

DROP

Will cause the output voltage to drop for the number of cycles
specified. The maximum number of cycles is 10.

OFF

Set the output voltage to zero at the zero crossing of the waveform.

ON 0

Will return the Voltage to the original setting if the voltage is turned
off by the OFF command.

ON1

Will return the Voltage to the original setting at the zero crossing of
the waveform if the voltage was turned off by the OFF command.

ON2

Will return the Voltage to the original setting at the peak of the
waveform if the voltage was turned off by the OFF command.

SYNC0

Sets the clock mode to internal. This command cannot be combined
with other commands in a single message string.

SYNC1

Sets the AUXILIARY unit in a clock and lock system to external
clock mode. This command can only be send to the auxiliary unit in
a clock and lock system. Units without the CLOCK option will
generate an error. This command cannot be combined with other
commands in a single message string.

GAL

Goto Alternate Language. This command switched the power
source interface back to SCPI mode. This command can not be
combined with other commands in a single message string.

Measurement commands for single-phase units (9012)
These commands can not be combined with other commands in a
single message string.

TEST 0

Returns the measured frequency.

TEST 1

Returns phase A measured voltage.

TEST 2

Returns phase B measured voltage.

TEST 3

Returns phase C measured voltage.

TEST 4

Returns phase A measured current.

TEST 5

Returns phase B measured current.

TEST 6

Returns phase C measured current.

TEST 7

Returns phase A measured power.

TEST 8

Returns phase B measured power.