beautypg.com

Rtca/do-160d (-160) – AMETEK Lx Series II Programming Manual User Manual

Page 192

background image

Programming Manual

Lx \ Ls Series II

188

8.4

RTCA/DO-160D (-160)

The following are the remote commands available for the -160 test option. The ABORt command
will terminate the test in progress at any time. See the Lx / Ls Series II User Manual (P/N 7004-
980) for more details about the implementation of each 160 test step.

Note: Only revision C and D are implemented in firmware and as such have specific SCPI

commands assiated with it. The revision E implementation (see section 8.5) is
implemented through the LxGui Windows program only and there are no SCPI commands
for it. Refer to the Avionics Software Manual (CI P/N 4994-971) for more information.

8.4.1 Command Tree

DO160

:NORMal

:VOLT_FREQ

:MINinum

:MAXimum

:VOLTage

UNBalance

:WAVeform :DISTortion

:VOLTage

:MODulation

:INTerrupt

:SURGe

:FREQency

:MODulation

:TRANSient

:VARiation

:EMERgency

:VOLT_FREQ

:MINimum

:MAXimum

:VOLTage

:UNBalance

:ABNormal stage

:VOLTage

:MINimum

:MAXimum

:UNDer

:OVER

:UNBalance

:FREQuency

:TRANsient

:STANdard

:GROup