Command Syntax

STATus:QUEStionable:NTRansition

STATus:QUEStionable:PTRansition

Parameters

0 to 32727

Default Value

0

Examples

STAT:QUES:NTR 16

STAT:QUES:PTR 512

Query Syntax

STATus:QUEStionable:NTRansition?

STATus:QUEStionable:PTRansitiion?

Returned Parameters

(Register value)

Related Commands

STAT:QUES:ENAB

Bit
Position

15 13

12

11

10

9

8-5

4

3

2

1

0

Bit Name

not

used

CL

rms

Rail

not

used

RI

not

used

TO

UNR

not

used

OCP

OV

Bit Weight

4096

2048

512

16

8

2

1

Table 4-5: Bit Configuration of Questionable Instrument Summary Registers

OV = over-voltage protection has tripped

OCP = over-current protection has tripped

UNR = output is unregulated

TO = over-temperature protection has tripped

RI = remote inhibit is active

Rail = loss of input phase voltage detected

CL rms = rms current limit is active

STATus:QUEStionable:INSTrument:ISUMmary?

Phase Selectable

This command returns the value of the Questionable Event register for a specific output of a
three-phase AC source. The particular output phase must first be selected by INST:NSEL.

The Event register is a read-only register which holds (latches) all events that are passed by the
Questionable NTR and/or PTR filter. Reading the Questionable Event register clears it.

Query Syntax

STATus:QUEStionable:INSTrument:ISUMmary[:EVENt]?

Parameters

None

Returned Parameters

(Register Value)

Examples

STAT:QUES:INST:ISUM:EVEN?

Related Commands

*CLS STAT:QUES:INST:ISUM:NTR STAT:QUES:INST:ISUM:PTR