Programming Manual

Lx \ Ls Series II

192

8.4.3 DO160 Emergency Test Commands

DO160:EMERgency:VOLT_FREQ:MINimum

This command will set the voltage and frequency to the minimum level for the emergency
operation.

Command Syntax

DO160:EMERgency:VOLT_FREQ:MINimum

Parameters

none

Examples

DO160:EMER:VOLT_FREQ:MIN

Query Syntax

none

DO160:EMERgency:VOLT_FREQ:MAXimum

This command will set the voltage and frequency to the maximum level for the emergency
operation.

Command Syntax

DO160:EMERgency:VOLT_FREQ:MAXimum

Parameters

none

Examples

DO160: EMER:VOLT_FREQ:MAX

Query Syntax

none

DO160: EMERgency:VOLTage:UNBalance

This command will unbalance the voltage level for each phase to the emergency high and low
operating voltage of each phase. This test is valid only for three phase AC source.

Command Syntax

DO160:EMERgency:VOLTage:UNBalance

Parameters

none

Examples

DO160: EMER:VOLT:UNB

Query Syntax

none