AMETEK Lx Series II Programming Manual User Manual
Page 174

Programming Manual
Lx \ Ls Series II
170
8.2.9 APE Program Headers
The table below shows the APE headers, the phase selection extension and available arguments.
If the phase extension(s) do not follow the header, the command will be applied to all available
phases.
HEADER
EXTENSION ARGUMENT
DEFINITION
AMP
A, B, C
# or numeric data
from 0.0 to RNG
value.
Amplitude in volts
CAL or
CAL AMP
A, B, C
# or numeric data
from 0.0 to 4095
Calibration Coefficient for output voltage
(Range was 0 to 255 on L Series)
CAL VLT
A, B, C
Expected
Actual voltage at remote sense
CAL CUR
A, B, C
Expected
Actual current from power source
CAL PWR
A, B, C
Expected
Actual power from power source
(Not available on Ls Series)
CLK
INT, EXT
Clock source
CRL
A, B, C
Numeric value 0.00
to 100.0 (maximum
available current)
Current limit in Amps
DLY
Numeric data from
0,00 to 9999
Delay in seconds
DRP
A, B, C
1 through 5
Number of dropped periods.
FRQ
Numeric data from
45.00 or LLM to HLM
value
Frequency in Hertz.
MOD
PHS
1 or 3
Programs the output phase configuration
PHZ
A, B, C
# or numeric data
from 0.0 to ±999.9
Phase angle in degrees
PRG
0 through 15
Register load
REC
0 through 15
Recall register
REG
0 through 15c
Register load
RNG
A, B, C
0.0 to limit value of
range
Amplitude range and limit value in volts
SNC
INT, EXT
Synchronize
SRQ
0, 1, 2
Service request disable, enable or at
completion of program.
STP
From parameter
minimum to
maximum value
Step size
TLK
Any program header
or other argument
Setup AC source to talk argument when
talk addressed.
TRG