beautypg.com

AMETEK Lx Series II Programming Manual User Manual

Page 137

background image

Programming Manual

Lx \ Ls Series II

133

2. Set the triggered level of the function that will generate the transient. For example, if the

previously programmed voltage function is going to step the output voltage amplitude to 135
volts upon receipt of a trigger, use:

VOLTage:TRIGger 135

3. Select the trigger source that will generate the trigger. For example, to select the external

Trigger In1 SMA connector as the trigger source, use:

TRIGger:TRANsient:SOURce EXTernal

Trigger sources are discussed in detail under "Triggering Output Changes".

4. Only perform this step if you have selected PULSE as the transient mode in Step 1. Specify

the pulse count, the pulse period, and then either the duty cycle or the pulse width using the
following commands:

PULSe:COUNt 1

specifies 1 output pulse

PULSe:PERiod 1

specifies a pulse period of 1 second

PULSe:DCYCle 50

specifies a duty cycle of 50%

PULSe:WIDTh .5

specifies a pulse width of .5 seconds (not necessary in this case
since a duty cycle has already been specified)

5. Initiate the transient trigger system to enable it to receive a trigger. To enable the trigger

system for one transient event use:

INITiate:IMMediate:SEQuence1

6. To enable the transient system indefinitely use:

INITiate:CONTinuous:SEQuence1 ON

Trigger the transient. This is described in detail under "Triggering Output Changes".

Example

The following example programs a voltage dropout for 2 cycles of a 120 volt, 60 Hz output. The
dropout begins at the positive peak of the output voltage waveform (90 degrees phase) and is
triggered by IEEE-488 bus trigger.

*RST

Begin at power-on state

VOLT 120

Set initial output voltage (immediate-level)

FREQ 60

Set initial output frequency

OUTP ON

Enable the output

VOLT:MODE PULS

Enable output to generate pulses when triggered

VOLT:TRIG 0

Set the voltage dropout (triggered level)

PULS:WIDT .03333

Set pulse width for 2 periods

TRIG:SOUR BUS

Respond to IEEE-488 bus triggers

TRIG:SYNC:SOUR PHAS

Synchronize triggers to internal phase reference

TRIG:SYNC:PHAS 90

Sets internal phase reference point to 90 degrees

INIT:SEQ1

Set to Wait-for-trigger state

Send the IEEE-488 bus trigger