SENSe:SWEep:OFFSet:POINts

Parameters

4096 through 2E9 | MINimum | MAXimum

*RST Value

0

Examples

SENS:SWE:OFFS:POIN -2047

Query Syntax

SENSe:SWEep:OFFSet:POINts?

Returned Parameters

Related Commands

SENS:SWE:TINT

MEAS:ARR

SENSe:SWEep:TINTerval

This command defines the time period between samples. The sample period can be programmed
from 10.42 to 104.2 microseconds in 10 microsecond increments in single-phase mode and from
31.25 to 312.5 microseconds in three-phase mode.

All the MEASure commands use the ACQuire trigger sequence implicitly.

Command Syntax

SENSe:SWEep:TINTerval

Parameters

10.42 through 104.2 (microseconds)

*RST Value

10.42 µs or 31.25 µs

Examples

SENS:SWE:TINT 100

Query Syntax

SENSe:SWEep:TINTerval?

Returned Parameters

Related Commands

SENS:SWE:OFFS:POIN

MEAS:ARR