VOLTage:TRIGgered
Phase Selectable
This command selects the ac rms amplitude that the output waveform will be set to during a
triggered step or pulse transient.
The maximum peak voltage that the AC source can output is 425 V peak. This includes any
combination of voltage, and function shape values. Therefore, the maximum value that can be
programmed depends on the peak-to-rms ratio of the selected waveform. For a sinewave, the
maximum voltage that can be programmed is 300 V rms.
Note: You cannot program a voltage that produces a higher volt-second on the output than a
300V rms sinewave.
Command Syntax
[SOURce:]VOLTage[:LEVel]:TRIGgered :AMPLitude]
Parameters
0 to 300 (for sinewaves)
Unit
V (rms voltage)
*RST Value
0 volt
Examples
VOLT:TRIG 120 VOLT:LEV:TRIG 120
Query Syntax
SOURce:]VOLTage[:LEVel]:TRIGgered:AMPLitude]?
Returned Parameters
returned.
Related Commands
VOLT VOLT:MODE
FUNC:SHAP
VOLTage:MODE
Phase Selectable
This command determines how the ac rms output voltage is controlled during a triggered output
transient. The choices are:
FIXed
The voltage is unaffected by a triggered output transient.
STEP
The voltage is programmed to the value set by VOLTage:TRIGgered
when a triggered transient occurs.
PULSe
The voltage is changed to the value set by VOLTage:TRIGgered for a
duration determined by the pulse commands.
LIST
The voltage is controlled by the voltage list when a triggered transient
occurs.
Command Syntax
[SOURce:]VOLTage:MODE
Parameters
FIXed | STEP | PULSe | LIST
*RST Value
FIX
Examples
VOLT:MODE LIST
VOLT:MODE FIX
Query Syntax
[SOURce:]VOLTage:MODE?
Returned Parameters
Related Commands
VOLT:TRG
VOLT