Sense subsystem - sweep – AMETEK Lx Series II Programming Manual User Manual
Page 73

Programming Manual
Lx \ Ls Series II
69
4.15 Sense Subsystem - Sweep
This subsystem controls the measurement current range and the data acquire sequence of the
AC source.
Subsystem Syntax
SENSe
[:COUPle] AC | DC
ADC coupling mode.
:SWEep
:OFFSet
Define trigger delay in time relative to start of the
digitizer data record
:POINts
Define trigger points relative to the start of the
digitizer data record
:TINTerval
Sets the digitizer sample spacing
SENSe[:COUPle]
This command sets the coupling mode for the ADC of the measurement system. Available
coupling modes are AC or DC. Factory default is DC coupled. This command requires firmware
revision 0.95 or higher.
Command Syntax
SENSe[:COUPle]
Parameters
AC | DC
*RST Value
DC
Examples
SENS:COUP DC
Query Syntax
SENS:COUP?
Returned Parameters
Related Commands
SENS:SWE:TINT
SENSe:SWEep:OFFSet
This command defines the trigger point expressed in seconds relative to the start of the returned
data record when an acquire trigger is used. The values can range from MIN to MAX depending
on the phase mode and the selected sample interval. When the values are negative, the values in
the beginning of the data record represent samples taken prior to the trigger.
Command Syntax
SENSe:SWEep:OFFSet
Parameters
*RST Value
0
Examples
SENS:SWE:OFFS -12E-3
Query Syntax
SENSe:SWEep:OFFSet?
Returned Parameters
Related Commands
SENS:SWE:TINT
MEAS:ARR
SENSe:SWEep:OFFSet:POINts
This command defines the trigger point expressed in sample points relative to the start of the
returned data record when an acquire trigger is used. The values can range from -4095 to 2E9.
When the values are negative, the values in the beginning of the data record represent samples
taken prior to the trigger.