beautypg.com

AMETEK Lx Series II Programming Manual User Manual

Page 201

background image

Programming Manual

Lx \ Ls Series II

197

:FREQuency

[:LEVel]

:MODulation

:TRANsient

:VOLTage

[:LOW]

:HIGH

:FREQuency

[:LOW]

:HIGH

:VERSion D | E | F

8.6.2 MIL704 General Commands

MIL704:VERSion

This command will select the required test standard version. The version selection must be set
prior to any test selection.

Available revsions are D, E and F.

Command Syntax

MIL704:VERSion

Parameters

D | E | F

Examples

MIL704:VERS E

Query Syntax

MIL704:VERS?

Returned Parameters

MIL704:FREQuency

This command will selects the nominal test frequency. For revisions D and E, the only available
setting is 400 Hz. For revision F (draft), available settings are 60 Hz, 400 Hz or variable frequency.
The nominal frequency selection must be set prior to any test execution.

Command Syntax

MIL704:FREQuency

Parameters

60HZ | 400HZ | VFRequency

Examples

MIL704:FREQ VFR

Query Syntax

MIL704:FREQ?

Returned Parameters