beautypg.com

AMETEK Lx Series II Programming Manual User Manual

Page 69

background image

Programming Manual

Lx \ Ls Series II

65

OUTPut:TTLTrg:MODE

This command sets the operation of the Trigger Out1 signal to either Function Strobe or Trigger
mode. Factory default is Trigger state which means the OUTP:TTLT:STAT command is required
to generate outputs. This mode is compatible with the Agilent HP6834B models. In Function
Strobe mode, an output pulse is generated automatically any time an output parameter such as
voltage, frequency or phase is programmed. The AC source Trigger Out1 signal is available at a
SMA connector on the rear of the Lx\Ls Series units.

Command Syntax

OUTPut:TTLTrg:MODE TRIG | FSTR

Parameters

TRIG | FSTR

*RST Value

TRIG

Examples

OUTP:TTLT:MODE FSTR

Query Syntax

OUTPut:TTLTrg:MODE?

Returned Parameters

Related Commands

OUTP:TTLT:STAT