Programming Manual

Lx \ Ls Series II

52

Query Syntax

MEASure[:SCALar]:CURRent:AC?

FETCh[:SCALar]:CURRent:AC?

Parameters

None

Examples

MEAS:CURR:AC?

FETC:CURR:AC?

Returned Parameters

Related Commands

INST:NSEL

MEASure:CURRent:ACDC?
FETCh:CURRent:ACDC?

Phase Selectable

These queries return the ac and dc components of the rms current being sourced at the output
terminals.

Query Syntax

MEASure[:SCALar]:CURRent:ACDC?

FETCh[:SCALar]:CURRent:ACDC?

Parameters

None

Examples

MEAS:CURR:ACDC? FETC:CURR:ACDC?

Returned Parameters

Related Commands

INST:NSEL

MEASure:CURRent:AMPLitude:MAXimum?
FETCh:CURRent:AMPLitude:MAXimum?

Phase Selectable

These queries return the absolute value of the peak current as sampled over one measurement
acquisition of 4096 data points. Note that the MEAS format returns the non-recurring peak current
(as in a peak hold reading). This value can be cleared with the MEAS:CURR:AMP:RES
command. The FETC format can be used to obtain the recurring or repetitive peak current this
requires the acquisition to be triggered first by either an INIT:ACQ or a MEAS command for
another paramter e.g. current, followed by the FETC:CURR:AMPL:MAX?

Query Syntax

MEASure[:SCALar]:CURRent:AMPLitude:MAXimum?

FETCh[:SCALar]:CURRent:AMPLitude:MAXimum?

Parameters

None

Examples

MEAS:CURR:AMPL:MAX?

FETC:CURR:AMPL:MAX?

Returned Parameters

Related Commands

INST:NSEL

MEASure:CURRent:AMPLitude:RESet
FETCh:CURRent:AMPLitude:RESet

Phase Selectable

These command resets the peak current hold value returned with the MEAS:CURR:AMPL:MAX?
query.

Syntax

MEASure[:SCALar]:CURRent:AMPLitude:RESet

FETCh[:SCALar]:CURRent:AMPLitude:RESet

Parameters

None

Examples

MEAS:CURR:AMPL:RES

Returned Parameters

None

Related Commands

MEAS:CURR:AMPL:MAX?

FETC:CURR:AMPL:MAX?

MEASure:CURRent:CREStfactor?
FETCh:CURRent:CREStfactor?

Phase Selectable