AMETEK Lx Series II Programming Manual User Manual
Page 91
Programming Manual
Lx \ Ls Series II
87
Phase Selectable
This command sets the output phase when a triggered step or pulse transient occurs. The phase
of the output voltage waveform is expressed relative to an internal reference. The phase angle is
programmed in degrees. Positive phase angles are used to program the leading phase, and
negative phase angles are used to program the lagging phase.
The PHASe command is not influenced by INSTrument:COUPle ALL. It applies only to the current
output phase selected by INSTrument:NSELect.
Command Syntax
[SOURce:]PHASe:TRIGgered
Parameters
-360° through +360°
*RST Value
triggered phase ø1 = 0°, triggered
phase ø2 = 120°, triggered phase ø3 = 240°
Examples
PHAS:TRIG 120
PHASE MAX
Query Syntax
[SOURce:]PHASe:TRIGgered?
Returned Parameters
Related Commands
PHAS:MODE
PHAS