beautypg.com

AMETEK Lx Series II Programming Manual User Manual

Page 91

background image

Programming Manual

Lx \ Ls Series II

87

Phase Selectable

This command sets the output phase when a triggered step or pulse transient occurs. The phase
of the output voltage waveform is expressed relative to an internal reference. The phase angle is
programmed in degrees. Positive phase angles are used to program the leading phase, and
negative phase angles are used to program the lagging phase.

The PHASe command is not influenced by INSTrument:COUPle ALL. It applies only to the current
output phase selected by INSTrument:NSELect.

Command Syntax

[SOURce:]PHASe:TRIGgered

Parameters

-360° through +360°

*RST Value

triggered phase ø1 = 0°, triggered

phase ø2 = 120°, triggered phase ø3 = 240°

Examples

PHAS:TRIG 120

PHASE MAX

Query Syntax

[SOURce:]PHASe:TRIGgered?

Returned Parameters

Related Commands

PHAS:MODE

PHAS