AMETEK Lx Series II Programming Manual User Manual
Page 193
Programming Manual
Lx \ Ls Series II
189
8.4.2 DO160 Normal Test Commands
DO160:NORMal:VOLT_FREQ:MINimum
This command will set the voltage and frequency to the minimum level for the normal operation.
Command Syntax
DO160:NORMal:VOLT_FREQ:MINimum
Parameters
none
Examples
DO160:NORM:VOLT_FREQ:MIN
Query Syntax
none
DO160:NORMal:VOLT_FREQ:MAXimum
This command will set the voltage and frequency to the maximum level for the normal operation.
Command Syntax
DO160:NORMal:VOLT_FREQ: MAXimum
Parameters
none
Examples
DO160:NORM:VOLT_FREQ:MAX
Query Syntax
none
DO160:NORMal:VOLTage:UNBalance
This command will unbalance the voltage level for each phase to the normal high and low
operating voltage of each phase. This test is valid only for three phase AC source.
Command Syntax
DO160:NORMal:VOLTage:UNBalance
Parameters
none
Examples
DO160:NORM:VOLT:UNB
Query Syntax
none
DO160:NORMal:WAVeform:DISTortion
This command will set the voltage distortion to 5% for the duration of the test.
Command Syntax
DO160:NORMal:WAVeform:DISTortion
Parameters
none
Examples
DO160:NORM:WAV:DIST
Query Syntax
none
DO160:NORMal:VOLTage:MODulation
This command will cause output voltage modulation. The level of modulation is the function of the
rate of modulation. Refer to Figure 8-4 in the User Manual. The command parameter is the rate
of modulation in Hz.
Command Syntax
DO160:NORMal:VOLTage:MODulation
Parameters
Examples
DO160:NORM:VOLT:MOD 20
Query Syntax
DO160:NORM:VOLT:MOD?
Returned Parameters