Volume Left: Trims volume for Left output. E.g. Volume –6dB + Volume Left +1dB = -5dB
Range is -12dB to + 6dB in 1dB steps. Default is 0dB.
Volume Right: Trims volume for Right output. E.g. Volume –6dB + Volume Right -1dB = -7dB
Range is -12dB to + 6dB in 1dB steps. Default is 0dB.
NOTE: The above notes apply to cameras configured with Rev B audio hardware. Cameras shipped
prior to Sept 15 2008 (and not yet upgraded to Rev B) were supplied with Rev A audio hardware,
with the following operational restrictions.
-
For maximum output signal quality, only use high impedance headphones.
USB-2 MASTER
This port permits the camera to operate as the Slave camera in a Master / Slave camera pair. To establish
control, plug the square end of a USB-2 cable into the lower USB port of the RED ONE camera to act as a
Slave, and the rectangular end of a USB-2 cable into the upper USB port of the RED ONE camera to act
as the Master. Then power cycle both cameras. On boot up the two cameras will automatically establish
Master / Slave mode.
Once connected using the USB cable, User Interface commands and remote triggers received by the
Master camera are transmitted to the Slave camera.
SUPPORTED COMMANDS
Supported commands include:
PROJECT
SENSOR
TRANSPORT
TIME BASE
QUALITY
RESOLUTION
ISO (SENSITIVITY)
COLOR TEMP
TINT
GENLOCK ENABLE
SHUTTER MODE
SHUTTER SPEED
SHUTTER SYNCRO
SHUTTER PHASE
RECORD
GPI RECORD TRIGGER
PRE-RECORD
PLAY
FAST FORWARD
FAST REVERSE
NEXT CLIP
PREV CLIP
EXIT
NOTE: When not used in this mode, the GUI status of the Slave camera will update to reflect new
values transmitted from the Master camera, but the GUI menus do not follow.
NOTE: When used in Master / Slave mode, each of the cameras should still be provided with
Genlock (tri-level sync) and External Timecode signals.
NOTE: Media formatting must be performed independently for each camera. The Master / Slave
mode will not format the media attached to two cameras at the same time.
USB-2 SLAVE
This port permits the camera to operate as the Slave camera in a Master / Slave camera pair. To establish
control, plug the square end of a USB-2 cable into the lower USB port of the RED ONE camera to act as a
Slave, and the rectangular end of a USB-2 cable into the upper USB port of the RED ONE camera to act
as the Master. Then power cycle both cameras. On boot up the two cameras will automatically establish
Master / Slave mode.