Point staking summary – Spectra Precision Survey Pro CE v3.6 User Manual User Manual
Page 70
User’s Manual
64
d. The rod man needs to move back by 0.2
feet to be over the design point. Rather
than take another shot, we will instruct
him to use a tape and place a stake at
that location. Tap the
6WRUH7DSH«
button to store the point.
e. Enter the following data in the Store
Point (Tape Offset) Dialog Box:
Point Name
:
6
Description
:
Staked
Tape Out/Tape In (+/-)
:
0.2
and tap
6WRUH. This will result in coordinates for the stored
point that are 0.2 feet further from the total station than the
last shot to the prism.
Note: The default value in the
Tape Out/Tape In
field should put you
directly over the design point, assuming you are on line.
Note: Negative
Tape Out/Tape In
values are toward the total station
and positive values are away from the total station.
Point Staking Summary
1. Open a job that contains the design points that you want to stake.
2. Check the job settings.
3. Setup a backsight.
4. Stake the points from the Stake Points screen.