Turn to – Spectra Precision Survey Pro CE v3.6 User Manual User Manual
Page 261
Survey Pro Reference Manual
R-104
7XUQ 7R : opens the Turn To screen, described below, where the total
station can be turned to a specified direction or quickly flipped
between face one and face two.
;
Show Distance
: When checked, distances will continuously
measured and displayed on the data collector along with the angles.
Note: distances are always measured when a shot is taken,
regardless of the
Shoot Distance
checkbox setting.
Turn To
6XUYH\ 5HPRWH &RQWURO 7XUQ 7R
The Turn To screen is used to turn a robotic total station to a
specified horizontal and zenith angle, or to a specified point.
Horizontal Angle
: is the horizontal angle that the
total station will turn to.
Zenith Angle
: is the zenith angle that the total
station will turn to.
7XUQ WR $QJOHV : turns the total station to the
specified horizontal and zenith angles.
Existing Point
: is the point from the current job
that the total station will turn to.
7XUQ WR 3RLQW : turns the total station to the
specified point.
7XUQ WR %DFNVLJKW : turns the total station to the backsight point.
)OLS : quickly rotates the total station from face one to face two, or
vice versa.