Corner & plane – Spectra Precision Survey Pro CE v3.6 User Manual User Manual
Page 249
Survey Pro Reference Manual
R-92
Corner & Plane
6XUYH\ &RUQHU 3ODQH
The Corner and Plane screen is used to store a
point using a reflectorless total station for a
point that cannot be shot, but three points on the
same plane can be shot.
Foresight
: is the name of the point that will be
stored.
Description
: is the description for the point that
will be stored.
HR: 0.000
: shows that no rod height will be used
with this routine since all shots are direct
reflectorless.
6KRRW 3ODQH : will prompt you to take three shots on the same flat
surface that the new point is located.
Note: Each shot can be in any location on the same
plane, but they must not form a straight line and they
should not be grouped close together.
$LP DW &RUQHU : will prompt you to aim at the corner (the
point that you want to store). Although no shot is taken,
the angles to the point will be used to compute its
location.
Note: After all shots are done, the computed elevation is
displayed for the new point. You can either enter a
different elevation or tap
2. to accept the computed
elevation.
%DFNVLJKW : accesses the Backsight Setup screen (Page R-72) where
the current backsight can be modified.
Aim at target
(no shot)
Shot 1
Shot 2
Shot 3
Corner & Plane