Spectra Precision Survey Pro CE v3.6 User Manual User Manual
Page 59
Fieldwork
53
Note: When creating a new job, it is important that the
Units for
Distances
field be set to the correct units. This allows you to
seamlessly switch between different units in mid-job.
Problems can arise if these units are inadvertently set to the incorrect
units prior to entering new data. For example, assume you created a
control file by hand-entering a list of coordinates in a new job where
the job was set to
Feet
and the coordinates were in
US Survey Feet
.
Now assume you created another new job and correctly set it to
US
Survey Feet
. If you then selected the previous job as a control file for
the new job, the display of all of the coordinates in the control file
would be converted from Feet to US Survey Feet.
e. Accept the default coordinates for the
first job point by tapping
)LQLVK .
2. Check the Job Settings.
a. Tap
-RE , 6HWWLQJV from the Main
Menu to open the Settings screen.
b. Tap
the
Instrument
tab and make sure
both the
Brand
and
Model
fields are set
to
Manual Mode
.
c. For this example, tap the
Surveying
Settings
and un-check all the checkboxes.
d. Tap
2. to save the job settings.
3. Add a backsight point to the job.
a. Select
-RE , (GLW 3RLQWV from the Main Menu.