Spectra Precision Survey Pro CE v3.6 User Manual User Manual
Page 109
Screen Examples
103
measurement that varied the most from the average from all the
shots taken.
5. Optional – The particular measurement with the worst residual
can be removed and consequently not used when computing the
coordinates for the foresight point by tapping the corresponding
7RVV button. After tossing a measurement, the
Average (of)
and
Worst Residual
values are recomputed (assuming there is still
data from at least three shots remaining).
6. Optional – You can re-shoot the specified number of sets, and only
collect the horizontal angle, zenith angle, or slope distance from
all the shots by tapping the
+$, =$, or 6' button, respectively.
This will replace all of the current shot data only for the selected
data type with new data. You can even change the number of
sets before shooting the new data.
7. Once you are satisfied with your shot data, tap
6LGH 6KRW to store
the new foresight point as a side shot, or tap
7UDYHUVH to store it
as a traverse shot.