beautypg.com

Staking points – Spectra Precision Survey Pro CE v3.6 User Manual User Manual

Page 67

background image

Fieldwork

61

a. Access

the

6XUYH\ , %DFNVLJKW 6HWXS

screen from the Main Menu.

b. In

the

Occupy

Point

field, enter

1

as the

point name.

c. Toggle

the

%6 'LUHFWLRQ

/

%6 3RLQW

button to

%6 'LUHFWLRQ

and enter

0

as

the backsight azimuth.

d. Enter

an

HI

and

HR

of

5

feet.

e. Leave

the

Fixed HR at Backsight

field

unchecked.

f. Confirm that the

Backsight Circle

value is zero. If it displays a

non-zero value, tap the

%DFNVLJKW &LUFOH

button and set it to

zero.

g. Tap

6ROYH . A map view will open that shows a graphical

representation of the occupy point and backsight direction.
Tap

&ORVH to continue.

Staking Points

4. Stake the first design point (Point 2).

a. Access

the

6WDNHRXW , 6WDNH 3RLQWV

screen. The backsight

information is displayed near the bottom
of the screen. At this point, it is
assumed that your total station is over
the occupy point and its horizontal angle
was zeroed while aiming toward the
backsight.

b. Enter the following data in the Stake

Points screen:

Design point

:

2

Increment

:

1

Height of rod

:

5

and tap

6ROYH ! .