Staking points – Spectra Precision Survey Pro CE v3.6 User Manual User Manual
Page 67
Fieldwork
61
a. Access
the
6XUYH\ , %DFNVLJKW 6HWXS
screen from the Main Menu.
b. In
the
Occupy
Point
field, enter
1
as the
point name.
c. Toggle
the
%6 'LUHFWLRQ
/
%6 3RLQW
button to
%6 'LUHFWLRQ
and enter
0
as
the backsight azimuth.
d. Enter
an
HI
and
HR
of
5
feet.
e. Leave
the
Fixed HR at Backsight
field
unchecked.
f. Confirm that the
Backsight Circle
value is zero. If it displays a
non-zero value, tap the
%DFNVLJKW &LUFOH
button and set it to
zero.
g. Tap
6ROYH . A map view will open that shows a graphical
representation of the occupy point and backsight direction.
Tap
&ORVH to continue.
Staking Points
4. Stake the first design point (Point 2).
a. Access
the
6WDNHRXW , 6WDNH 3RLQWV
screen. The backsight
information is displayed near the bottom
of the screen. At this point, it is
assumed that your total station is over
the occupy point and its horizontal angle
was zeroed while aiming toward the
backsight.
b. Enter the following data in the Stake
Points screen:
Design point
:
2
Increment
:
1
Height of rod
:
5
and tap
6ROYH ! .