beautypg.com

Move ms (move multisample), For more information, see “move ms – KORG Electronic Keyboard User Manual

Page 629

background image

Sampling: Page Menu Commands MS Mono To Stereo/MS Stereo To Mono (Change Multisample Type)

619

The multisample will be converted into a program
whose Oscillator Mode (Program 1–1b) is Single.
If “Use Destination Program Parameters” is
checked:
Executing this command will replace the
multisample of the convert destination program
with the multisample selected here, and will not
initialize the remaining program parameters. Use
this setting if you wish to use the parameter settings
of an existing preset program, etc.

If you check “Use Destination Program
Parameters,” be aware of the following points.

The Oscillator Mode of the convert-destination
program must be Single. If you attempt to execute
this command when these conditions are not
satisfied, a message will indicate “Oscillator Mode
conflicts.” You will need to change the Oscillator
Mode
setting of the convert destination program.

5. In To “Program,” select the convert destination

program.
When the edit cell is selected, you can use the
numeric keys 0–9, the VALUE dial, the VALUE
slider, and

/

switches to make a selection.

When you press the popup button, the Program
Select menu will appear. Here you can select a
program by bank.

It is recommended that you use USER-B as the
program bank for Sampling mode.

6. To execute the Convert Multisample To Program

command, press the OK button. To cancel, press
the Cancel button.

MS Mono To Stereo/MS Stereo To Mono
(Change Multisample Type)

This command converts a mono multisample to stereo,
or a stereo multisample to mono. If the selected
multisample is mono, the dialog box will allow you to
execute “MS Mono To Stereo.” If the selected
multisample is stereo, the dialog box will allow you to
execute “MS Stereo To Mono.”

1. Use “Multisample Select (MS)” (0–1a) to select the

multisample that you want to change to stereo or
mono.

2. Choose either “MS Mono To Stereo” or “MS

Stereo To Mono” to open the dialog box.

3. To execute the Change Multisample Type

command, press the OK button. To cancel, press
the Cancel button.
When you execute this command, the multisample
type and sample assignment will change as follows.

MS Mono To Stereo

• The selected multisample will be converted to

stereo. The last two characters of the multisample
name will be overwritten as -L.

• An identical multisample will be newly created, but

with the last two characters of the multisample
name overwritten as -R.

• Mono samples assigned to the original multisample

will be assigned to both -L and -R multisamples.

• If samples assigned to the original multisample are

part of a stereo pair of samples, the -L and -R
samples will be assigned to the -L and -R
multisamples.

: MS Stereo To Mono

• The selected multisample will be converted to

mono. The -L or -R at the end of the multisample
name will be deleted.

• Multisamples that are stereo pairs of the selected

multisample will be deleted.

Move MS (Move Multisample)

This command lets you move the currently selected
multisample to the specified number (i.e., to change
the multisample number), or to rearrange the
multisample numbers so that they start from 000 after
multisamples have become discontinuous as a result of
creating or editing. (See diagram below)

When you reassign the multisample numbers, the
multisample numbers within the programs that use
these multisamples will also be automatically
reassigned (according to the setting of step 4). (This
means that you do not need to reselect the
multisamples in Program mode following this
operation.)

1. Use “Multisample Select (MS)” (0–1a) to select the

multisample that you wish to move.

2. Select “Move MS” to open the dialog box.

3. In To “Multisample,” specify the move destination

multisample number.

When moving a stereo multisample, you will

need to move each part separately.

If you wish to rearrange all multisamples
consecutively, check “Optimize Empty Multisample
No.”

4. If “Adjust Multisample Assign in Program” is

checked and if the multisamples being moved are