CHAPTER 9 CLICK 110

Baud Rate (Bus 1 and 2)

The next two configuration parameters that come up in the front panel menu allow you to

manually set the baud rate of the two RS-485 buses. Bus 1 comes up first, with the green and

yellow LEDs coming on together; bus 2 comes up second, with the blue LED glowing solid.

Note

This parameter can also be changed using the DIP switches or Click Supervisor.

Level 1 LEDs

Baud rate for bus 1

Baud rate for bus 2

Level 2 LEDs

9600 bps (default)

19200 bps

38400 bps

57600 bps

LED off
LED on

Cancel and exit menu

Table 9.10 – Front Panel Menu Baud Rate Settings

See the earlier Navigating through the Menu and the Menu Operation Example sections for

how to configure this parameter.

Because this parameter can also be set by the DIP switches, you may need to ensure that the

DIP switches are set to Software configuration mode; if they are set to Hardware, the front

panel menu will be able to display but not change these settings.

Channel Enable

The next configurable parameter is enabling output channels. To select this parameter, re-

lease the push-button when the blue and yellow LEDs come on.

Note

This parameter can also be changed using the DIP switches or Click Supervisor.

A disabled output will never enter the detection state, and will never indicate a fault condi-

tion. Any combination of outputs can be enabled. Due to limited space on the side label,

This manual is related to the following products: