beautypg.com

Installation, Wiring into the ups module, Wiring out of the ups module – Wavetronix Click 400 (900 MHz radio) (CLK-400) - User Guide User Manual

Page 158

background image

CHAPTER 15 • CLICK 203

157

Note

The battery fuse must be removed when installing or replacing the module.

Installation

Use the following tables to wire the UPS and battery.

Wiring into the UPS Module

Terminal

Connection

L (+)

AC line (black) in

N (–)

AC neutral (white) in

Table 15.1 – Wiring into the UPS Module

Note

Ensure power to AC mains is disconnected while wiring the AC input.

Wiring out of the UPS Module

Terminal

Connection

+

+DC out (red)

-DC out (black)

Alarm

Active switching output (see Signaling Outputs section)

Bat.-Mode

Active switching output (see Signaling Outputs section)

Bat.-Charge

Active switching output (see Signaling Outputs section)

R1

Remote terminal (see Remote Shutdown section)

R2

Remote terminal (see Remote Shutdown section)

Table 15.2 – Wiring out of the UPS Module, 7-terminal Block

Terminal

Connection

Battery +

+DC to battery (red)

Battery –

-DC to battery (black)

Table 15.3 – Wiring Out of the UPS Module, 2-terminal Block