beautypg.com

Verify communication – Wavetronix Click 400 (900 MHz radio) (CLK-400) - User Guide User Manual

Page 151

background image

150

CHAPTER 13 CLICK 200

Figure 13.5 – Verifying Earth Ground

3 The resistance should measure less than one ohm. If not, the most likely problem is the

DIN rail is not making connection to earth ground through the chassis of the cabinet.

The Click 200 cards have a connector on the bottom that snaps on the DIN rail that provides

the connection to earth ground. If the DIN rail is not making a good connection to earth

ground, connect a 16 AWG (or larger) wire to the DIN rail with a bolt and run that wire

directly to an earth ground terminal.

Verify Communication

Follow the steps below to verify the communication connections:
1 Check the RS-232 connection by plugging a straight-through RS-232 cable between a

laptop and the DB-9 connector on the Click 200.

2 Launch SmartSensor Manager and connect via a serial connection. If there are prob-

lems connecting, verify that the cabling is set up correctly.

3 Check the RS-485 connection to the SmartSensor using a Click 304 RS-232 to RS-485

converter. Attach the Click 304 to the T-bus (see Chapter 2 for more on T-buses) and

then plug a straight-through RS-232 cable between a laptop and the DB-9 connector

on the faceplate of the Click 304.

4 Launch SmartSensor Manager and connect via a serial connection. If there are prob-

lems connecting, verify that the cabling is set up correctly.

Once communication and ground connections have been verified, the installation of the

Click 200 is complete.