CHAPTER 26 • CLICK 330/331 221

Status

Meaning

On

Supply voltage is in an acceptable range

Off

Supply voltage is too low

Table 25.1 – Power Monitor LEDs

˽

Each Ethernet port has two LEDs that show the data transmission speed of that port,

as shown in Table 25.2. These LEDs are labeled 100/ACT and 1000/ACT. If the LED

is on, there is an electrical link. If the LED blinks, there is currently network traffic at

that speed.

LED

10 Mbps

100 Mbps

1000 Mbps

100/ACT

On or blinking

On or blinking

Off

1000/ACT

On or blinking

Off

On or blinking

Table 25.2 – Ethernet Port Monitor LEDs

˽

The fiber ports on the Click 331 each have an LED labeled 1000 LNK/ACT. If this LED

is on, there is a valid connection through that port. If the LED blinks, there is currently

network traffic at 1000 Mbps.

Installation

Unlike many other Click devices, the Click 330/331 do not mount over the T-bus, meaning

that power and communications will have to be wired in.

Wiring Power and Communication

The first four screw terminals, marked US1, GND, US2 and GND, are for wiring in power.

The other two, which are labeled R1 and R2, are for security and functionality alarm pur-

poses (see Figure 25.3).

Figure 25.3 – Wiring the Click 330/331