CHAPTER 23 • CLICK 301
Figure 23.13 – Expert Driver Disconnect Tab
Setting
Description
Disconnect Mode
Allows you to set conditions under which the device should drop a con-
nection.
Ignore DTR, the default, indicates that the Modem Control In doesn’t
affect the connection.
DTR Drop sets the network connection to or from the serial port to
disconnect (drop) when Modem Control In transitions from an asserted
state to not asserted state.
Start Character
Provides a place to enter the start character that is used to signal the
active startup function (found under the Connect tab) to attempt to
connect.
Telnet Mode
Enables Telnet mode.
Port Password
Enables the use of a password on the serial port.
CTRL-D Disconnect
Drops the connection when Ctrl-D or Hex 04 is detected. Both Telnet
Com Port Cntrl and Check EOT (Ctrl+D) must be enabled for Disconnect
with EOT to function properly. Ctrl+D is only detected going from the
serial port to the network.
Hard Disconnect
Closes the TCP connection even if the remote site does not acknowl-
edge the disconnect request.
Inactivity Timeout
Sets the amount of time there can be no activity on the serial line
before the device drops the connection.
Telnet Name/Port
Password
Lets you enter either the Telnet name you’re using or the password for
the serial port, depending on which of those two boxes—
Telnet Mode or
Port Password—is checked.
Table 23.11 – Expert Driver Disconnect Tab
The Ethernet > Channel > Packing tab allows you to configure packing settings, as well as
to set other options (see Figure 23.14 and Table 23.12).
- Click 421 (bluetooth to serial converter) (CLK-421) - User Guide Click 342 (lean managed ethernet switch) (CLK-342) - User Guide Click 341 (lean managed ethernet switch) (CLK-341) - User Guide Click 340 (lean managed ethernet switch) (CLK-340) - User Guide Click 331 (unmanaged ethernet switch) (CLK-331) - User Guide Click 330 (unmanaged ethernet switch) (CLK-330) - User Guide Click 304 (RS-232 to RS-485 converter) (CLK-304) - User Guide Click 305 (RS-232 to RS-485 converter) (CLK-305) - User Guide Click 301 (serial to ethernet converter) (CLK-301) - User Guide Click 100 (16 output contact closure) (CLK-100) - User Guide Click 104 (4-channel DIN rail contact closure) (CLK-104) - User Guide Click 110 (4-channel contact closure eurocard) (CLK-110) - User Guide Click 112 (detector rack card) (CLK-112) - User Guide Click 114 (detector rack card) (CLK-114) - User Guide Click 120 (screw terminal relay) (CLK-120) - User Guide Click 121 (spring cage relay) (CLK-121) - User Guide Click 200 (surge suppression) (CLK-200) - User Guide Click 201 (1 amp AC to DC converter) (CLK-201) - User Guide Click 202 (2 amp AC to DC converter) (CLK-202) - User Guide Click 203 (UPS and battery) (CLK-203) - User Guide Click 204 (4 amp AC to DC converter) (CLK-204) - User Guide Click 210 (AC circuit breaker) (CLK-210) - User Guide Click 211 (AC outlet) (CLK-211) - User Guide Click 221 (DC surge protector) (CLK-221) - User Guide Click 222 (system surge protector) (CLK-222) - User Guide Click 223 (dual-485 surge protector) (CLK-223) - User Guide Click 230 (AC surge protector) (CLK-230) - User Guide Click 250 (wireless surge protector) (CLK-250) - User Guide