Wavetronix Click 400 (900 MHz radio) (CLK-400) - User Guide User Manual
Page 115
114
CHAPTER 10 • CLICK 112/114
S4: Input Mapping
1
2
3
4
Channel
Off
Off
Off
Off
Software mode
Off
Off
Off
On
1–2
Off
Off
On
Off
3–4
Off
Off
On
On
5–6
Off
On
Off
Off
7–8
Off
On
Off
On
9–10
Off
On
On
Off
11–12
Off
On
On
On
13–14
On
Off
Off
Off
15–16
On
Off
Off
On
17–18
On
Off
On
Off
19–20
On
Off
On
On
21–22
On
On
Off
Off
23–24
On
On
Off
On
25–26
On
On
On
Off
27–28
Table 10.3 – Click 112 DIP Switch Channel Input Map Settings
S4: Input Mapping
1
2
3
4
Channel
Off
Off
Off
Off
Software mode
Off
Off
Off
On
1–4
Off
Off
On
Off
5–8
Off
Off
On
On
9–12
Off
On
Off
Off
13–16
Off
On
Off
On
17–20
Off
On
On
Off
21–24
Off
On
On
On
25–28
Table 10.4 – Click 114 DIP Switch Channel Input Map Settings
If any switch is on (up), Hardware mode is selected, meaning the inputs can only be mapped
using the DIP switches (as shown in the tables above), and Click Supervisor and the front
panel menu will be able to display the current setting, but not change it. If all switches are
off (down), Software mode is selected and Click Supervisor and the front panel menu will
be able to both display and change the current setting.
- Click 421 (bluetooth to serial converter) (CLK-421) - User Guide Click 342 (lean managed ethernet switch) (CLK-342) - User Guide Click 341 (lean managed ethernet switch) (CLK-341) - User Guide Click 340 (lean managed ethernet switch) (CLK-340) - User Guide Click 331 (unmanaged ethernet switch) (CLK-331) - User Guide Click 330 (unmanaged ethernet switch) (CLK-330) - User Guide Click 304 (RS-232 to RS-485 converter) (CLK-304) - User Guide Click 305 (RS-232 to RS-485 converter) (CLK-305) - User Guide Click 301 (serial to ethernet converter) (CLK-301) - User Guide Click 100 (16 output contact closure) (CLK-100) - User Guide Click 104 (4-channel DIN rail contact closure) (CLK-104) - User Guide Click 110 (4-channel contact closure eurocard) (CLK-110) - User Guide Click 112 (detector rack card) (CLK-112) - User Guide Click 114 (detector rack card) (CLK-114) - User Guide Click 120 (screw terminal relay) (CLK-120) - User Guide Click 121 (spring cage relay) (CLK-121) - User Guide Click 200 (surge suppression) (CLK-200) - User Guide Click 201 (1 amp AC to DC converter) (CLK-201) - User Guide Click 202 (2 amp AC to DC converter) (CLK-202) - User Guide Click 203 (UPS and battery) (CLK-203) - User Guide Click 204 (4 amp AC to DC converter) (CLK-204) - User Guide Click 210 (AC circuit breaker) (CLK-210) - User Guide Click 211 (AC outlet) (CLK-211) - User Guide Click 221 (DC surge protector) (CLK-221) - User Guide Click 222 (system surge protector) (CLK-222) - User Guide Click 223 (dual-485 surge protector) (CLK-223) - User Guide Click 230 (AC surge protector) (CLK-230) - User Guide Click 250 (wireless surge protector) (CLK-250) - User Guide