Wavetronix Click 400 (900 MHz radio) (CLK-400) - User Guide User Manual
Page 138
CHAPTER 12 • CLICK 172/174
137
1L (One Loop Speed)
Outputs contact closures for single-loop emulation. The duration of
each contact closure output is based upon the speed of the detected
vehicle (instead of the duration of the vehicle in the beam). The
duration of each contact output is based on the formula: duration in
seconds = nominal vehicle length in feet / actual speed in feet per
second. The nominal vehicle length is read from the sensor when this
mode is selected. To set the nominal vehicle length, use the Smart-
Sensor Manager software. The nominal length in feet is entered in
the default loop spacing field.
Table 12.1 – Click 172/174 Operation Modes
A dual-loop emulation system uses two rack card channel outputs to mimic the outputs
of a traditional dual-loop system. In a traditional system, a vehicle would travel over the
primary detector and then the secondary detector (see Figure 12.4).
Primary Detector
Secondary Detector
Traffic Direction
Figure 12.4 – Primary Leads Secondary
Figure 12.5 below shows a diagram of the output signal time waveforms of the two detec-
tors.
Primary
Channel
Secondary
Channel
Time
Dual-Loop Emulation System (Output Time Waveform)
Elapsed Time
(Indicates Speed)
Detection
Duration
On
Off
On
Off
Figure 12.5 – Emulation System Output Waveforms
The primary detector channel output would activate for the duration that the vehicle was
over the primary loop. Soon afterward, the secondary detector channel output would acti-
vate for the duration that the vehicle was over the secondary loop. The elapsed time between
the two activations indicates the speed of the vehicle. (The duration of the detection is based
upon the speed and length of the vehicle.)
- Click 421 (bluetooth to serial converter) (CLK-421) - User Guide Click 342 (lean managed ethernet switch) (CLK-342) - User Guide Click 341 (lean managed ethernet switch) (CLK-341) - User Guide Click 340 (lean managed ethernet switch) (CLK-340) - User Guide Click 331 (unmanaged ethernet switch) (CLK-331) - User Guide Click 330 (unmanaged ethernet switch) (CLK-330) - User Guide Click 304 (RS-232 to RS-485 converter) (CLK-304) - User Guide Click 305 (RS-232 to RS-485 converter) (CLK-305) - User Guide Click 301 (serial to ethernet converter) (CLK-301) - User Guide Click 100 (16 output contact closure) (CLK-100) - User Guide Click 104 (4-channel DIN rail contact closure) (CLK-104) - User Guide Click 110 (4-channel contact closure eurocard) (CLK-110) - User Guide Click 112 (detector rack card) (CLK-112) - User Guide Click 114 (detector rack card) (CLK-114) - User Guide Click 120 (screw terminal relay) (CLK-120) - User Guide Click 121 (spring cage relay) (CLK-121) - User Guide Click 200 (surge suppression) (CLK-200) - User Guide Click 201 (1 amp AC to DC converter) (CLK-201) - User Guide Click 202 (2 amp AC to DC converter) (CLK-202) - User Guide Click 203 (UPS and battery) (CLK-203) - User Guide Click 204 (4 amp AC to DC converter) (CLK-204) - User Guide Click 210 (AC circuit breaker) (CLK-210) - User Guide Click 211 (AC outlet) (CLK-211) - User Guide Click 221 (DC surge protector) (CLK-221) - User Guide Click 222 (system surge protector) (CLK-222) - User Guide Click 223 (dual-485 surge protector) (CLK-223) - User Guide Click 230 (AC surge protector) (CLK-230) - User Guide Click 250 (wireless surge protector) (CLK-250) - User Guide