CHAPTER 27 • CLICK 340/341/342 227

˽

US1 – Supply voltage for +US1

˽

GND – Ground for US1

˽

US2 – Supply voltage for +US2

˽

GND – Ground for US2

The other terminal block is reserved for alarm contacts and wiring earth ground:

˽

– Floating alarm contact

˽

– Floating alarm contact

˽

– Functional earth ground (optional)

˽

NC – Not connected

LEDs

There are two supply voltage LEDs labeled US1 and US2 at the top of each device. If the

supply voltage LEDs are on, the device is being supplied with sufficient voltage; if the LEDs

are off, the device is currently receiving less than 18 VDC.

Each Ethernet port has two diagnostic LEDs, which ensure that you always have sufficient

local information. When the top LED is on, there is an active link; if the top LED is off, then

the link is not active. The bottom LED indicates the data transmission rate (see Table 26.1).

LED

Color

Status

Description

RJ-45 top

Green

On

Link active

Off

Link not active

Blinking

Sending/receiving data

RJ-45 bottom

Yellow

On

Full duplex mode

Off

Half duplex mode

Blinking

Collision detect

Table 26.1 – Ethernet Port LEDs

The SC fiber ports also have two diagnostic LEDs (see Table 26.2).

LED

Color

Status

Description

SC fiber ports

Green or yellow

On

Link active

Off

Link not active

Blinking

Sending/receiving data

Table 26.2 – SC Fiber Port LEDs

Installation

Unlike many other Click devices, the Click 340, 341 and 342 do not mount over the T-bus,