180

CHAPTER 21 CLICK 230

Note

The Click 230 is designed for use with 120 VAC. A 220 VAC version is available for
installations using that voltage. See your Wavetronix dealer for details.

Protection is achieved through the use of tightly coordinated hybrid circuits consisting of

fast-responding surge-arresting diodes (SAD), high-powered current-handling gas dis-

charge tubes (GDT) and series decoupling elements.

Physical Features

The Click 230 has eight active screw terminal connections. The module is wired in through

terminals 1, 3 and 5, and out through terminals 2, 4 and 6. Terminals 11 and 12, also on the

OUT side, are for testing.

Figure 21.2 – Diagram of the Click 230

Installation

1 Connect the black (line) wire from the Click 210 circuit breaker to the rightmost screw

terminal (terminal 5) on the IN side of the Click 230.