beautypg.com

Wavetronix Click 400 (900 MHz radio) (CLK-400) - User Guide User Manual

Page 91

background image

90

CHAPTER 9 CLICK 110

Note

This parameter can also be changed using the front panel menu or Click Supervisor.

As mentioned earlier, the Click 110 device receives serial datagrams from a SmartSensor.

These datagrams can contain many channels of detection data.

Because the Click 110 has four output channels, only four input datagram channels, re-

ceived from the sensor, can be output by each device. (If you need more than four channels,

consider using multiple devices.) As shown in the table below, the outputs are mapped

sequentially—that is, they can only be mapped in numerically ordered groups of four (1–4,

5–8, etc.). If you chose, for example, 17–20, then input 17 would be mapped to output 1,

input 18 would be mapped to output 2, input 19 would be mapped to output 3, and input

20 would be mapped to output 4.

If fewer than four outputs are required, any contact closure output can be disabled. A dis-

abled output will never enter the detection state, and will never indicate a fault condition.

Depending on whether each channel is enabled or disabled, the input mapped to it will also

be enabled or disabled.

S3: Channel Input Map

1

2

3

4

Channel

Off

Software mode

On

Off

Off

Off

1–4

On

Off

Off

On

5–8

On

Off

On

Off

9–12

On

Off

On

On

13–16

On

On

Off

Off

17–20

On

On

Off

On

21–24

On

On

On

Off

25–28

On

On

On

On

29–32

Table 9.4 – DIP Switch Channel Input Map Settings

If switch 1 (S3:1) is on (up), Hardware mode is selected, meaning the inputs can be mapped

using the DIP switches (as shown in Table 9.4 above), and Click Supervisor and the front

panel menu will be able to display the current setting, but not change it. (Dashes in the table

above indicate that the other three switches don’t affect Software mode selection.)

If switch 1 is off (down), Software mode is selected and Click Supervisor and the front panel

menu will be able to both display and change the current setting.

This manual is related to the following products: