CHAPTER 10 • CLICK 112/114

121

Level 1 LEDs

Autobaud

Level 2 LEDs

Cancel and exit menu

Autobaud on bus 1

LED off
LED on

Autobaud on bus 2

Table 10.9 – Front Panel Menu Autobaud Settings

See the earlier Navigating through the Menu and the Menu Operation Example sections for

how to configure this parameter.

As each baud rate is attempted, the Level 2 LEDs will sequence with a single LED illumi-

nated from LED 1–4.

If the Click 112/114 is successful in communicating with a SmartSensor, it will display

the baud rate found, using the same Level 2 LED pattern used in selecting the baud rate

(covered in the Baud Rate section of this chapter and Table 10.10). After a short time of

displaying the autobaud results, the menu will return to normal operation with the baud

rate setting updated (and stored) to the baud rate detected during the autobaud process.

If the autobaud fails, all four Level 2 LEDs will light up for a few seconds, and then the

menu will return to normal operation with the baud rate setting remaining unchanged.

Note

If the baud rate of either of the RS-485 buses was configured using the DIP switches
(so that parameter is set to Hardware mode), the Level 2 LED configuration options
for that bus will not be displayed (the LED option will never come on). If both RS-485
buses are configured using the DIP switches, the Level 1 LED menu option for auto-
baud will not be displayed (the green LED option will never come on).

Baud Rate (Bus 1 and 2)

The next two configuration parameters that come up in the front panel menu allow you to

manually set the baud rate of the two RS-485 buses. Bus 1 comes up first, with the yellow

LED coming on solid, then bus 2, with the yellow LED flashing.

Note

This parameter can also be changed using the DIP switches or Click Supervisor.